Specifications |
Control system | Performance and function highly integrated Current Vector General Purpose Inverter. |
Drive performance | Induction motor and Synchronous motor. |
Maximum frequency | Vector control: 0~300Hz; V/F control: 0~3200Hz. |
Wave-carrier frequency | 0.5kHz~16kHz; Depending on load, can automatically adjust wave-carrier frequency. |
Input frequency resolution | Digital setting: 0.01Hz; analog setting: maximum frequency×0.025%. |
Control mode | Open vector control(SVC); Closed loop vector control(FVC); V/F control. |
Starting torque | G type: 0.5Hz/150%(SVC); 0Hz/180%(FVC). P type: 0.5Hz/100%. |
Speed range | 1: 100(SVC) 1: 1000(FVC) |
Speed stability accuracy | ±0.5%(SVC) ±0.02%(FVC) |
Torque control accuracy | ±5%(FVC) |
Overload capacity | G type: 150%rated current60s; 180%rated current3s; P type: 120%rated current60s; 150%rated current3s. |
Torque boost | Automatic or manual 0.1%~30.0%, |
V/F curve | Straight-line V/F curve Multi-point V/F curve N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, 2 power square) |
V/F separation | Two types: complete separation; half separation. AVR output. |
Ramp mode | Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0–6500.0s |
DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0–36.0s Braking action current value: 0.0%–100.0% |
JOG control | JOG frequency range: 0.00–50.00 Hz JOG acceleration/deceleration time: 0.0–6500.0s |
Easy PLC, multiple speeds | Up to 16 speeds via the simple PLC function or combination of DI terminal states |
Onboard PID | Process-controlled closed loop control system |
Auto voltage regulation (AVR) | Keep constant output voltage automatically when grid voltage fluctuates. |
Overvoltage/ Overcurrent stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage / overcurrent. |
Fast current limit function | Protect inverter from overcurrent malfunctions. |
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the FVC mode. |
Power dip ride through | The load feedback energy compensates the voltage reduction so that the Invertercan continue to run for a short time. |
Timing control | Time range: 0.0–6500.0 minutes |
Two-motor switchover | Two motors can be switched over via two groups of motor parameters. |
Fieldbus | Supports RS485, Profibus-DP, CANlink, CANopen (need extention cards) |
Background software | Change inverter parameter & vitual oscillograph to monitor inverter status. |
Command source | Operation panel Control terminals Serial communication port You can perform switchover between these sources in various ways |
Frequency source | 11 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. You can perform switchover between these sources in various ways. |
Auxiliary frequency source | 11 auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis. |
Input terminal | 6 digital input (DI) terminals, DI5 supports up to 100 kHz high-speed pulse input; 3 analog input (AI) terminals, support 0–10 V voltage input or 4–20 mA current input |
Output terminal | 2 digital output (DO) terminal (FM supports 0–10 kHz square wave signal output) 1 relay output terminal 2 analog output (AO) terminal that support 0–20 mA current output or 0–10 V voltage. |
LED display | Displays parameters. |
Key lock | It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. |
Protection function | Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection and overload protection |
Optional parts | PG card, brake unit, RS485 card, CAN card, Profibus-DP card |
Location | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt. |
Altitude | Lower than 1000m. |
Ambient temperature | -10°C to +40°C (de-rated if the ambient temperature is between 40°C and 50°C) |
Humidity | Less than 95%RH, without condensing |
Vibration | Less than 5.9m/s2 (0.6g). |
Storage temperature | -20℃~+60℃. |